Installation methods for the QLogic v8.xx.xx driver
29
Installing and Configuring the QLogic HBA and v8.x-Series Driver
Installation methods for the QLogic v8.xx.xx driver
The QLogic v8.xx.xx driver may be installed onto a Linux host using
one of the two following methods:
Method One - Use the QLogic DKMS RPM to compile and install
the modular driver for Dell servers running RHEL 4.0 systems
and attached to EMC Storage Arrays.
This method requires no manual edits for Dell servers attached to
EMC Storage Arrays. By installing the DKMS RPM, the necessary
files will be edited and the driver will be compiled and installed
automatically.
Method Two - Use the QLogic RPM to compile and install the
modular driver for RHEL 4, SLES 9, and SLES 10.
This method requires no manual edits for systems attached to
EMC Storage Arrays. By installing the QLogic RPM, the
necessary files will be edited and the driver will be compiled and
installed automatically.
Note: Prior to installing the QLogic driver, processes holding the driver open
must be stopped so that the currently-loaded driver may be removed from
the running kernel.
Perform the following steps prior to the installation:
1. Stop all I/O.
2. Unmount all filesystems attached to the QLogic driver.
3. If the Naviagent/CLI is installed and enabled on the host, then
the Naviagent/CLI service must be stopped.
To stop the Naviagent/CLI service, issue one of the two following
commands:
/etc/init.d/naviagentcli stop
or
service naviagentcli stop
4. If PowerPath is installed and enabled on the host, then the
PowerPath service must be stopped.