EMC FC5300 User Manual Page 1

Browse online or download User Manual for Servers EMC FC5300. EMC FC5300 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 134
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
EMC Enterprise Storage
EMC Corporation 171 South Street, Hopkinton, MA 01748-9103
Corporate Headquarters: (508) 435-1000, (800) 424-EMC2 Fax: (508) 435-5374 Service: (800) SVC-4EMC
EMC Fibre Channel Storage Systems
Models FC4500, FC5300, and FC5700
CONFIGURATION PLANNING GUIDE
P/N 014003039-02
Page view 0
1 2 3 4 5 6 ... 133 134

Summary of Contents

Page 1 - CONFIGURATION PLANNING GUIDE

EMC Enterprise StorageEMC Corporation 171 South Street, Hopkinton, MA 01748-9103Corporate Headquarters: (508) 435-1000, (800) 424-EMC2 Fax: (508)

Page 2 - Trademark Information

xEMC Fibre Channel Storage-System Configuration Planning GuideTables

Page 3 - Contents

55-16EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareiDAE Data SheetYou can use a rackmount or deskside DPE and D

Page 4

5Hardware Data Sheets5-17Storage System HardwarePower cables (single or dual)ac inlet connector: IEC 320-C14 power inletDeskside power cord: USA: 1.8

Page 5

55-18EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareDAE Data SheetThe DAE storage-system dimensions and requirem

Page 6

5Hardware Data Sheets5-19Storage System HardwarePower cables (single or dual)ac inlet connector: IEC 320-C14 power inletDeskside power cord: USA: 1.8

Page 7

55-20EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareCabinets for Rackmount EnclosuresPrewired 19-inch-wide cabin

Page 8

5Cable and Configuration Guidelines5-21Storage System HardwareCable and Configuration GuidelinesWe recommend that all copper-interconnected nodes be c

Page 9

55-22EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareYou can use any existing FDDI, multimode, 62.5 micron cable

Page 10

5Cable and Configuration Guidelines5-23Storage System HardwareTable 5-4 Cable Sizes — CopperComponent planning diagrams and worksheets follow.Length T

Page 11

55-24EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareHardware Planning WorksheetsFollowing are worksheets to note

Page 12

5Hardware Planning Worksheets5-25Storage System HardwareHardware Component Worksheet for Shared StorageNumber of servers:____ Adapters in servers:____

Page 13 - Networks (SANs)

EMC Fibre Channel Storage-System Configuration Planning GuidexixiPrefaceThis planning guide provides an overview of Fibre Channel disk-array storage-s

Page 14 - Storage System Models

55-26EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-12 Sample Shared Storage InstallationSwitch 2Switch

Page 15 - Fibre Channel Background

5Hardware Planning Worksheets5-27Storage System HardwareHardware for Unshared StorageThe cable identifiers used in the following figure and on the fol

Page 16 - Interconnect Components

55-28EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-13 Cable Identifier — Unshared System without HubsA

Page 17

5Hardware Planning Worksheets5-29Storage System HardwareFigure 5-14 Cable Identifier — Unshared Full-Fibre System with HubsHub 2Hub 1AdapterAdapterAda

Page 18 - SP SP

55-30EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareHardware Component Worksheet for Unshared StorageNumber of s

Page 19 - 16-Port Switch, Back View

5Hardware Planning Worksheets5-31Storage System HardwareFigure 5-15 Sample Unshared Deskside System — Basic ConfigurationSample Component WorksheetA1

Page 20 - Nine-Port Hub

55-32EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-16 Sample Unshared Deskside System — Dual-Adapter/D

Page 21 - Hardware)

5Hardware Planning Worksheets5-33Storage System HardwareSample Component WorksheetHardware Component Worksheet for Unshared StorageNumber of servers:

Page 22

55-34EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-17 Sample Component Worksheet for DPE-Based System

Page 23 - Networks)

5Hardware Planning Worksheets5-35Storage System HardwareWhat Next? This chapter explained hardware components of shared and unshared storage systems.

Page 24 - Storage Groups

xiiEMC Fibre Channel Storage-System Configuration Planning GuidePrefaceOrganization of the ManualChapter 1 Provides background information on the Fibr

Page 25 - Sample SAN Configuration

55-36EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System Hardware

Page 26

Storage-System Management6-16This chapter explains the management applications you can use to manage storage systems from servers. Topics are • Using

Page 27

66-2EMC Fibre Channel Storage-System Configuration PlanningStorage-System ManagementNavisphere software lets you bind and unbind disks, manipulate cac

Page 28 - About Unshared Storage

6Using Navisphere Manager Software6-3Storage-System ManagementUsing Navisphere Manager SoftwareNavisphere Manager software (Manager) lets you manage m

Page 29

66-4EMC Fibre Channel Storage-System Configuration PlanningStorage-System ManagementFigure 6-1 Sample Shared Switched Environment with Navisphere Mana

Page 30

6Storage Management Worksheets6-5Storage-System ManagementStorage Management WorksheetsThis section includes two worksheets: one for shared storage an

Page 31 - Tradeoffs

66-6EMC Fibre Channel Storage-System Configuration PlanningStorage-System ManagementFor unshared storage (unshared direct or shared-or-clustered direc

Page 32 - Introducing RAID

6Storage Management Worksheets6-7Storage-System ManagementManagement Utility Worksheet – Unshared StorageHostname: Operating system:Storage system typ

Page 33 - RAID Groups and

66-8EMC Fibre Channel Storage-System Configuration PlanningStorage-System Management

Page 34 - RAID Types

EMC Fibre Channel Storage Systems Configuration Planning Guidei-1Aac power requirementsDAE-only storage system 5-18DPE storage system 5-14iDAE stora

Page 35 - RAID 5 Group

About Fibre Channel Storage Systems and Networks (SANs)1-11This chapter introduces Fibre Channel disk-array storage systems and storage area networks

Page 36 - RAID 3 Group

EMC Fibre Channel Storage Systems Configuration Planning Guidei-2Indexsite requirements 5-18weight 5-18data sheets, hardware 5-14device name, opera

Page 37 - RAID 1 Mirrored Pair

i-3EMC Fibre Channel Storage Systems Configuration Planning GuideIndexiDAEstorage system 5-16high availabilityoptions for unshared storage 5-13share

Page 38 - RAID Types and Tradeoffs

EMC Fibre Channel Storage Systems Configuration Planning Guidei-4IndexPpage size, cache 3-14, 4-13parallel access array, see RAID 3 Grouppaths to LUN

Page 39 - Hot Spare

i-5EMC Fibre Channel Storage Systems Configuration Planning GuideIndexSP (storage processor)description 5-5, 5-9FC-AL address ID 3-14, 4-12SPS (stan

Page 40

EMC Fibre Channel Storage Systems Configuration Planning Guidei-6Index

Page 41 - How a Hot Spare Works

11-2EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)Introducing EMC Fibre Channel Storag

Page 42 - RAID Benefits and Tradeoffs

1Fibre Channel Background1-3About Fibre Channel Storage Systems and Networks (SANs)Fibre Channel BackgroundFibre Channel is a high-performance serial

Page 43 - Performance

11-4EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)Fibre Channel Storage ComponentsA Fi

Page 44 - Storage Flexibility

1Fibre Channel Storage Components1-5About Fibre Channel Storage Systems and Networks (SANs)The maximum length of copper cable is 30 meters (99 feet) b

Page 45

11-6EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)You can cascade switches (connect on

Page 46

1Fibre Channel Storage Components1-7About Fibre Channel Storage Systems and Networks (SANs)Figure 1-4 A Switch ZoneIf you do not define a zone in a sw

Page 47 - Guidelines for RAID Types

EMC Fibre Channel Storage Systems Configuration Planning GuideiiCopyright © EMC Corporation 2000, 2001. All rights reserved.Printed May 2001No part of

Page 48

11-8EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)If your servers and storage systems

Page 49

1Fibre Channel Storage Components1-9About Fibre Channel Storage Systems and Networks (SANs)Storage Component (Storage Systems, Storage Processors (SPs

Page 50

11-10EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)Types of Storage System Installatio

Page 51 - Switched Storage

1About Switched Shared Storage and SANs (Storage Area Networks)1-11About Fibre Channel Storage Systems and Networks (SANs)About Switched Shared Storag

Page 52 - Dual Paths to LUNs

11-12EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)However, switch zoning cannot selec

Page 53

1About Switched Shared Storage and SANs (Storage Area Networks)1-13About Fibre Channel Storage Systems and Networks (SANs)Figure 1-10 Sample SAN Confi

Page 54

11-14EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)The following figure shows both dat

Page 55

1About Switched Shared Storage and SANs (Storage Area Networks)1-15About Fibre Channel Storage Systems and Networks (SANs)Storage System Hardware for

Page 56 - Application and LUN Planning

11-16EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)About Unshared StorageUnshared stor

Page 57

1About Unshared Storage1-17About Fibre Channel Storage Systems and Networks (SANs)Figure 1-13 Storage System Hardware for Unshared StorageWhat Next? F

Page 58

EMC Fibre Channel Storage Systems Configuration Planning GuideiiiPreface...

Page 59

11-18EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)

Page 60

RAID Types and Tradeoffs2-12This chapter explains RAID types you can choose for your storage system LUNs. If you already know about RAID types and kno

Page 61 - LUN Details Worksheet

22-2EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsIntroducing RAIDThe storage system uses RAID (redundant array of in

Page 62

2Introducing RAID2-3RAID Types and TradeoffsRAID Groups and LUNsSome RAID types let you create multiple LUNs on one RAID Group. You can then allot eac

Page 63 - 0_5, 0_6, 0_7, 0_8, 0_9

22-4EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsRAID TypesYou can choose from the following RAID types: RAID 5, RAI

Page 64

2RAID Types2-5RAID Types and TradeoffsFigure 2-2 RAID 5 GroupRAID 5 Groups offer excellent read performance and good write performance. Write performa

Page 65

22-6EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsThe following figure shows user and parity data with a data block s

Page 66

2RAID Types2-7RAID Types and TradeoffsFor each write to a RAID 3 Group, the storage system1. Calculates the parity data.2. Writes the new user and par

Page 67

22-8EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsRAID 0 Group (Nonredundant Array)A RAID 0 Group consists of three t

Page 68

2RAID Types2-9RAID Types and TradeoffsFigure 2-5 RAID 1/0 Group (Mirrored RAID 0 Group)A RAID 1/0 Group can survive the failure of multiple disks, pro

Page 69 - Direct Storage

EMC Fibre Channel Storage Systems Configuration Planning GuideivContentsRAID 1 Mirrored Pair ...

Page 70 - Dual SPs and Paths to LUNs

22-10EMC Fibre Channel Storage-System Configuration PlanningRAID Types and Tradeoffsreplace the failed disk, the SP copies the data from the former ho

Page 71

2RAID Types2-11RAID Types and TradeoffsFigure 2-6 How a Hot Spare WorksHot spare0123456789101112131415161718191. RAID 5 group consists of disk modules

Page 72

22-12EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsRAID Benefits and TradeoffsThis section reviews RAID types and exp

Page 73

2RAID Benefits and Tradeoffs2-13RAID Types and TradeoffsTable 2-1 Performance, Availability, and Cost of RAID Types (Individual Unit = 1.0)Performance

Page 74 - LUN Planning Worksheet

22-14EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsWe do not recommend using RAID 3 in the same storage-system chassi

Page 75 - Full-fibre storage system

2RAID Benefits and Tradeoffs2-15RAID Types and Tradeoffsspace usage is critical, bind an individual unit or RAID 0 Group without software mirroring.A

Page 76

22-16EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsFigure 2-7 Disk Space Usage in the RAID ConfigurationsA RAID 0 Gro

Page 77

2Guidelines for RAID Types2-17RAID Types and TradeoffsGuidelines for RAID TypesTo decide when to use a RAID 5 Group, RAID 3 Group, mirror (that is, a

Page 78

22-18EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsUse a RAID 0 Group (nonredundant individual access array) for appl

Page 79

2Sample Applications for RAID Types2-19RAID Types and TradeoffsSample Applications for RAID TypesThis section describes some types of applications in

Page 80

vEMC Fibre Channel Storage Systems Configuration Planning GuideContentsHardware for Unshared Storage...

Page 81

22-20EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsRAID 0 Group (nonredundant individual access array) — Use a RAID 0

Page 82

Planning File Systems and LUNs with Shared Switched Storage3-13This chapter shows a sample RAID, LUN, and Storage Group configuration with shared stor

Page 83

33-2EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StorageDual Paths to LUNsA shared stora

Page 84

3Sample Shared Switched Installation3-3Planning File Systems and LUNs with Shared Switched StorageSample Shared Switched InstallationThe following fig

Page 85 - Hardware

33-4EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StorageThe storage-system disk IDs and

Page 86 - Shared and Unshared Storage

3Sample Shared Switched Installation3-5Planning File Systems and LUNs with Shared Switched StorageMail Server — 576 Gbytes on four LUNsUnit O on five

Page 87 - Hardware for Shared Storage

33-6EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StoragePlanning Applications, LUNs, and

Page 88

3Planning Applications, LUNs, and Storage Groups3-7Planning File Systems and LUNs with Shared Switched StorageApplication and LUN Planning WorksheetA

Page 89 - Storage Processor (SP)

33-8EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StorageRAID type of LUN. This is the RA

Page 90 - Hardware for Unshared Storage

3Planning Applications, LUNs, and Storage Groups3-9Planning File Systems and LUNs with Shared Switched StorageLUN and Storage Group Planning Worksheet

Page 91

EMC Fibre Channel Storage Systems Configuration Planning GuideviContents

Page 92

33-10EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StoragePart of a sample LUN and Storag

Page 93 - Disks and Disk IDs

3Planning Applications, LUNs, and Storage Groups3-11Planning File Systems and LUNs with Shared Switched StorageStorage Group will be dedicated (not ac

Page 94

33-12EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StorageLUN Details WorksheetStorage sy

Page 95

3Planning Applications, LUNs, and Storage Groups3-13Planning File Systems and LUNs with Shared Switched StorageLUN Details WorksheetStorage system (co

Page 96

33-14EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StorageCompleting the LUN Details Work

Page 97

3Planning Applications, LUNs, and Storage Groups3-15Planning File Systems and LUNs with Shared Switched StorageLUN ID. The LUN ID is a hexadecimal num

Page 98 - Hardware Data Sheets

33-16EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched Storageper RAID Group may adversely im

Page 99

3Planning Applications, LUNs, and Storage Groups3-17Planning File Systems and LUNs with Shared Switched StorageFile system, partition, or drive. Write

Page 100 - Power requirements

33-18EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched Storage

Page 101 - Service clearances

Planning LUNs and File Systems with Unshared Direct Storage4-14Invisible Body Tag This chapter shows sample RAID and LUN configurations with direc

Page 102 - DAE Data Sheet

EMC Fibre Channel Storage-System Configuration Planning Guidevii1-1 Storage System Models ...

Page 103

44-2EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageDual SPs and Paths to LUN

Page 104 - Storage System Hardware

4Unshared Direct and Shared-or-Clustered Direct Storage4-3Planning LUNs and File Systems with Unshared Direct StorageThe storage system disk IDs and L

Page 105

44-4EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StoragePlanning Applications and

Page 106

4Planning Applications and LUNs4-5Planning LUNs and File Systems with Unshared Direct StorageApplication and LUN Planning WorksheetA sample worksheet

Page 107

44-6EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageRAID configuration. For e

Page 108 - Hardware Planning Worksheets

4Planning Applications and LUNs4-7Planning LUNs and File Systems with Unshared Direct StorageLUN Planning Worksheet - RackmountFull-fibre storage syst

Page 109

44-8EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageLUN Planning Worksheet -

Page 110

4Planning Applications and LUNs4-9Planning LUNs and File Systems with Unshared Direct StorageA sample LUN worksheet follows.Completing the LUN Plannin

Page 111

44-10EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageLUN Details WorksheetSto

Page 112

4Planning Applications and LUNs4-11Planning LUNs and File Systems with Unshared Direct StorageLUN Details WorksheetStorage system (complete this secti

Page 113

viiiEMC Fibre Channel Storage-System Configuration Planning GuideFigures5-8 Storage System with Two SPs Connected to the Same Server ... 5-

Page 114

44-12EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageCompleting the LUN Detai

Page 115 - 0__ _m or ft

4Planning Applications and LUNs4-13Planning LUNs and File Systems with Unshared Direct Storageyou would specify 80 Mbytes for the read cache and 160 M

Page 116 - Configuration

44-14EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageFor example,• A five-dis

Page 117

4Planning Applications and LUNs4-15Planning LUNs and File Systems with Unshared Direct Storageunits that will benefit from it. Read and write caching

Page 118

44-16EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct Storage

Page 119 - 4___ PSs:___4__SPSs:_

Storage System Hardware5-15Invisible Body Tag This chapter describes the storage-system hardware components. Topics are• Hardware for Shared Stor

Page 120

55-2EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareThe storage systems attach to the server and the interconnect

Page 121 - Management

5Hardware for Shared Storage5-3Storage System HardwareHardware for Shared StorageThe primary hardware component for shared storage is a ten-slot Disk-

Page 122 - Storage-System Management

55-4EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-3 Rackmount System with DPE and DAEsDisksThe disks —

Page 123

5Hardware for Shared Storage5-5Storage System HardwareDisk Modules and Module IDs — Rackmount DPE-Based SystemStorage Processor (SP)The SP provides th

Page 124 - Switch fabric

EMC Fibre Channel Storage-System Configuration Planning Guideix2-1 Performance, Availability, and Cost of RAID Types (Individual Unit = 1.0) ...

Page 125 - Storage Management Worksheets

55-6EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareHardware for Unshared StorageUnshared storage systems are les

Page 126

5Hardware for Unshared Storage5-7Storage System HardwareFigure 5-5 Storage System Types for Unshared StorageDeskside DPE with DAERackmount DPE, one en

Page 127

55-8EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareThe following figure shows some components of a deskside DPE.

Page 128

5Hardware for Unshared Storage5-9Storage System HardwareFigure 5-7 Disks and Disk IDsStorage Processor (SP)The SP provides the intelligence of the sto

Page 129

55-10EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-8 Storage System with Two SPs Connected to the Same

Page 130

5Planning Your Hardware Components5-11Storage System HardwareStorage-system caching provides significant performance enhancement. Read caching is avai

Page 131

55-12EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareConfiguration Tradeoffs - Unshared StorageFor each storage-s

Page 132

5Planning Your Hardware Components5-13Storage System HardwareTable 5-1 High-Availability Options, Deskside Unshared StorageFor rackmount systems, the

Page 133

55-14EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareHardware Data SheetsThe hardware data sheets shown in this s

Page 134

5Hardware Data Sheets5-15Storage System HardwarePower requirementsVoltage rating: 100 V ac to 240 V ac –10%/+15%, single-phase, 47 Hz to 63 Hz; power

Comments to this Manuals

No comments