EMC Enterprise StorageEMC Corporation 171 South Street, Hopkinton, MA 01748-9103Corporate Headquarters: (508) 435-1000, (800) 424-EMC2 Fax: (508)
xEMC Fibre Channel Storage-System Configuration Planning GuideTables
55-16EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareiDAE Data SheetYou can use a rackmount or deskside DPE and D
5Hardware Data Sheets5-17Storage System HardwarePower cables (single or dual)ac inlet connector: IEC 320-C14 power inletDeskside power cord: USA: 1.8
55-18EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareDAE Data SheetThe DAE storage-system dimensions and requirem
5Hardware Data Sheets5-19Storage System HardwarePower cables (single or dual)ac inlet connector: IEC 320-C14 power inletDeskside power cord: USA: 1.8
55-20EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareCabinets for Rackmount EnclosuresPrewired 19-inch-wide cabin
5Cable and Configuration Guidelines5-21Storage System HardwareCable and Configuration GuidelinesWe recommend that all copper-interconnected nodes be c
55-22EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareYou can use any existing FDDI, multimode, 62.5 micron cable
5Cable and Configuration Guidelines5-23Storage System HardwareTable 5-4 Cable Sizes — CopperComponent planning diagrams and worksheets follow.Length T
55-24EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareHardware Planning WorksheetsFollowing are worksheets to note
5Hardware Planning Worksheets5-25Storage System HardwareHardware Component Worksheet for Shared StorageNumber of servers:____ Adapters in servers:____
EMC Fibre Channel Storage-System Configuration Planning GuidexixiPrefaceThis planning guide provides an overview of Fibre Channel disk-array storage-s
55-26EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-12 Sample Shared Storage InstallationSwitch 2Switch
5Hardware Planning Worksheets5-27Storage System HardwareHardware for Unshared StorageThe cable identifiers used in the following figure and on the fol
55-28EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-13 Cable Identifier — Unshared System without HubsA
5Hardware Planning Worksheets5-29Storage System HardwareFigure 5-14 Cable Identifier — Unshared Full-Fibre System with HubsHub 2Hub 1AdapterAdapterAda
55-30EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareHardware Component Worksheet for Unshared StorageNumber of s
5Hardware Planning Worksheets5-31Storage System HardwareFigure 5-15 Sample Unshared Deskside System — Basic ConfigurationSample Component WorksheetA1
55-32EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-16 Sample Unshared Deskside System — Dual-Adapter/D
5Hardware Planning Worksheets5-33Storage System HardwareSample Component WorksheetHardware Component Worksheet for Unshared StorageNumber of servers:
55-34EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-17 Sample Component Worksheet for DPE-Based System
5Hardware Planning Worksheets5-35Storage System HardwareWhat Next? This chapter explained hardware components of shared and unshared storage systems.
xiiEMC Fibre Channel Storage-System Configuration Planning GuidePrefaceOrganization of the ManualChapter 1 Provides background information on the Fibr
55-36EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System Hardware
Storage-System Management6-16This chapter explains the management applications you can use to manage storage systems from servers. Topics are • Using
66-2EMC Fibre Channel Storage-System Configuration PlanningStorage-System ManagementNavisphere software lets you bind and unbind disks, manipulate cac
6Using Navisphere Manager Software6-3Storage-System ManagementUsing Navisphere Manager SoftwareNavisphere Manager software (Manager) lets you manage m
66-4EMC Fibre Channel Storage-System Configuration PlanningStorage-System ManagementFigure 6-1 Sample Shared Switched Environment with Navisphere Mana
6Storage Management Worksheets6-5Storage-System ManagementStorage Management WorksheetsThis section includes two worksheets: one for shared storage an
66-6EMC Fibre Channel Storage-System Configuration PlanningStorage-System ManagementFor unshared storage (unshared direct or shared-or-clustered direc
6Storage Management Worksheets6-7Storage-System ManagementManagement Utility Worksheet – Unshared StorageHostname: Operating system:Storage system typ
66-8EMC Fibre Channel Storage-System Configuration PlanningStorage-System Management
EMC Fibre Channel Storage Systems Configuration Planning Guidei-1Aac power requirementsDAE-only storage system 5-18DPE storage system 5-14iDAE stora
About Fibre Channel Storage Systems and Networks (SANs)1-11This chapter introduces Fibre Channel disk-array storage systems and storage area networks
EMC Fibre Channel Storage Systems Configuration Planning Guidei-2Indexsite requirements 5-18weight 5-18data sheets, hardware 5-14device name, opera
i-3EMC Fibre Channel Storage Systems Configuration Planning GuideIndexiDAEstorage system 5-16high availabilityoptions for unshared storage 5-13share
EMC Fibre Channel Storage Systems Configuration Planning Guidei-4IndexPpage size, cache 3-14, 4-13parallel access array, see RAID 3 Grouppaths to LUN
i-5EMC Fibre Channel Storage Systems Configuration Planning GuideIndexSP (storage processor)description 5-5, 5-9FC-AL address ID 3-14, 4-12SPS (stan
EMC Fibre Channel Storage Systems Configuration Planning Guidei-6Index
11-2EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)Introducing EMC Fibre Channel Storag
1Fibre Channel Background1-3About Fibre Channel Storage Systems and Networks (SANs)Fibre Channel BackgroundFibre Channel is a high-performance serial
11-4EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)Fibre Channel Storage ComponentsA Fi
1Fibre Channel Storage Components1-5About Fibre Channel Storage Systems and Networks (SANs)The maximum length of copper cable is 30 meters (99 feet) b
11-6EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)You can cascade switches (connect on
1Fibre Channel Storage Components1-7About Fibre Channel Storage Systems and Networks (SANs)Figure 1-4 A Switch ZoneIf you do not define a zone in a sw
EMC Fibre Channel Storage Systems Configuration Planning GuideiiCopyright © EMC Corporation 2000, 2001. All rights reserved.Printed May 2001No part of
11-8EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)If your servers and storage systems
1Fibre Channel Storage Components1-9About Fibre Channel Storage Systems and Networks (SANs)Storage Component (Storage Systems, Storage Processors (SPs
11-10EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)Types of Storage System Installatio
1About Switched Shared Storage and SANs (Storage Area Networks)1-11About Fibre Channel Storage Systems and Networks (SANs)About Switched Shared Storag
11-12EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)However, switch zoning cannot selec
1About Switched Shared Storage and SANs (Storage Area Networks)1-13About Fibre Channel Storage Systems and Networks (SANs)Figure 1-10 Sample SAN Confi
11-14EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)The following figure shows both dat
1About Switched Shared Storage and SANs (Storage Area Networks)1-15About Fibre Channel Storage Systems and Networks (SANs)Storage System Hardware for
11-16EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)About Unshared StorageUnshared stor
1About Unshared Storage1-17About Fibre Channel Storage Systems and Networks (SANs)Figure 1-13 Storage System Hardware for Unshared StorageWhat Next? F
EMC Fibre Channel Storage Systems Configuration Planning GuideiiiPreface...
11-18EMC Fibre Channel Storage-System Configuration PlanningAbout Fibre Channel Storage Systems and Networks (SANs)
RAID Types and Tradeoffs2-12This chapter explains RAID types you can choose for your storage system LUNs. If you already know about RAID types and kno
22-2EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsIntroducing RAIDThe storage system uses RAID (redundant array of in
2Introducing RAID2-3RAID Types and TradeoffsRAID Groups and LUNsSome RAID types let you create multiple LUNs on one RAID Group. You can then allot eac
22-4EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsRAID TypesYou can choose from the following RAID types: RAID 5, RAI
2RAID Types2-5RAID Types and TradeoffsFigure 2-2 RAID 5 GroupRAID 5 Groups offer excellent read performance and good write performance. Write performa
22-6EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsThe following figure shows user and parity data with a data block s
2RAID Types2-7RAID Types and TradeoffsFor each write to a RAID 3 Group, the storage system1. Calculates the parity data.2. Writes the new user and par
22-8EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsRAID 0 Group (Nonredundant Array)A RAID 0 Group consists of three t
2RAID Types2-9RAID Types and TradeoffsFigure 2-5 RAID 1/0 Group (Mirrored RAID 0 Group)A RAID 1/0 Group can survive the failure of multiple disks, pro
EMC Fibre Channel Storage Systems Configuration Planning GuideivContentsRAID 1 Mirrored Pair ...
22-10EMC Fibre Channel Storage-System Configuration PlanningRAID Types and Tradeoffsreplace the failed disk, the SP copies the data from the former ho
2RAID Types2-11RAID Types and TradeoffsFigure 2-6 How a Hot Spare WorksHot spare0123456789101112131415161718191. RAID 5 group consists of disk modules
22-12EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsRAID Benefits and TradeoffsThis section reviews RAID types and exp
2RAID Benefits and Tradeoffs2-13RAID Types and TradeoffsTable 2-1 Performance, Availability, and Cost of RAID Types (Individual Unit = 1.0)Performance
22-14EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsWe do not recommend using RAID 3 in the same storage-system chassi
2RAID Benefits and Tradeoffs2-15RAID Types and Tradeoffsspace usage is critical, bind an individual unit or RAID 0 Group without software mirroring.A
22-16EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsFigure 2-7 Disk Space Usage in the RAID ConfigurationsA RAID 0 Gro
2Guidelines for RAID Types2-17RAID Types and TradeoffsGuidelines for RAID TypesTo decide when to use a RAID 5 Group, RAID 3 Group, mirror (that is, a
22-18EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsUse a RAID 0 Group (nonredundant individual access array) for appl
2Sample Applications for RAID Types2-19RAID Types and TradeoffsSample Applications for RAID TypesThis section describes some types of applications in
vEMC Fibre Channel Storage Systems Configuration Planning GuideContentsHardware for Unshared Storage...
22-20EMC Fibre Channel Storage-System Configuration PlanningRAID Types and TradeoffsRAID 0 Group (nonredundant individual access array) — Use a RAID 0
Planning File Systems and LUNs with Shared Switched Storage3-13This chapter shows a sample RAID, LUN, and Storage Group configuration with shared stor
33-2EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StorageDual Paths to LUNsA shared stora
3Sample Shared Switched Installation3-3Planning File Systems and LUNs with Shared Switched StorageSample Shared Switched InstallationThe following fig
33-4EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StorageThe storage-system disk IDs and
3Sample Shared Switched Installation3-5Planning File Systems and LUNs with Shared Switched StorageMail Server — 576 Gbytes on four LUNsUnit O on five
33-6EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StoragePlanning Applications, LUNs, and
3Planning Applications, LUNs, and Storage Groups3-7Planning File Systems and LUNs with Shared Switched StorageApplication and LUN Planning WorksheetA
33-8EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StorageRAID type of LUN. This is the RA
3Planning Applications, LUNs, and Storage Groups3-9Planning File Systems and LUNs with Shared Switched StorageLUN and Storage Group Planning Worksheet
EMC Fibre Channel Storage Systems Configuration Planning GuideviContents
33-10EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StoragePart of a sample LUN and Storag
3Planning Applications, LUNs, and Storage Groups3-11Planning File Systems and LUNs with Shared Switched StorageStorage Group will be dedicated (not ac
33-12EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StorageLUN Details WorksheetStorage sy
3Planning Applications, LUNs, and Storage Groups3-13Planning File Systems and LUNs with Shared Switched StorageLUN Details WorksheetStorage system (co
33-14EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched StorageCompleting the LUN Details Work
3Planning Applications, LUNs, and Storage Groups3-15Planning File Systems and LUNs with Shared Switched StorageLUN ID. The LUN ID is a hexadecimal num
33-16EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched Storageper RAID Group may adversely im
3Planning Applications, LUNs, and Storage Groups3-17Planning File Systems and LUNs with Shared Switched StorageFile system, partition, or drive. Write
33-18EMC Fibre Channel Storage-System Configuration PlanningPlanning File Systems and LUNs with Shared Switched Storage
Planning LUNs and File Systems with Unshared Direct Storage4-14Invisible Body Tag This chapter shows sample RAID and LUN configurations with direc
EMC Fibre Channel Storage-System Configuration Planning Guidevii1-1 Storage System Models ...
44-2EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageDual SPs and Paths to LUN
4Unshared Direct and Shared-or-Clustered Direct Storage4-3Planning LUNs and File Systems with Unshared Direct StorageThe storage system disk IDs and L
44-4EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StoragePlanning Applications and
4Planning Applications and LUNs4-5Planning LUNs and File Systems with Unshared Direct StorageApplication and LUN Planning WorksheetA sample worksheet
44-6EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageRAID configuration. For e
4Planning Applications and LUNs4-7Planning LUNs and File Systems with Unshared Direct StorageLUN Planning Worksheet - RackmountFull-fibre storage syst
44-8EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageLUN Planning Worksheet -
4Planning Applications and LUNs4-9Planning LUNs and File Systems with Unshared Direct StorageA sample LUN worksheet follows.Completing the LUN Plannin
44-10EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageLUN Details WorksheetSto
4Planning Applications and LUNs4-11Planning LUNs and File Systems with Unshared Direct StorageLUN Details WorksheetStorage system (complete this secti
viiiEMC Fibre Channel Storage-System Configuration Planning GuideFigures5-8 Storage System with Two SPs Connected to the Same Server ... 5-
44-12EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageCompleting the LUN Detai
4Planning Applications and LUNs4-13Planning LUNs and File Systems with Unshared Direct Storageyou would specify 80 Mbytes for the read cache and 160 M
44-14EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct StorageFor example,• A five-dis
4Planning Applications and LUNs4-15Planning LUNs and File Systems with Unshared Direct Storageunits that will benefit from it. Read and write caching
44-16EMC Fibre Channel Storage Systems Configuration Planning GuidePlanning LUNs and File Systems with Unshared Direct Storage
Storage System Hardware5-15Invisible Body Tag This chapter describes the storage-system hardware components. Topics are• Hardware for Shared Stor
55-2EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareThe storage systems attach to the server and the interconnect
5Hardware for Shared Storage5-3Storage System HardwareHardware for Shared StorageThe primary hardware component for shared storage is a ten-slot Disk-
55-4EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-3 Rackmount System with DPE and DAEsDisksThe disks —
5Hardware for Shared Storage5-5Storage System HardwareDisk Modules and Module IDs — Rackmount DPE-Based SystemStorage Processor (SP)The SP provides th
EMC Fibre Channel Storage-System Configuration Planning Guideix2-1 Performance, Availability, and Cost of RAID Types (Individual Unit = 1.0) ...
55-6EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareHardware for Unshared StorageUnshared storage systems are les
5Hardware for Unshared Storage5-7Storage System HardwareFigure 5-5 Storage System Types for Unshared StorageDeskside DPE with DAERackmount DPE, one en
55-8EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareThe following figure shows some components of a deskside DPE.
5Hardware for Unshared Storage5-9Storage System HardwareFigure 5-7 Disks and Disk IDsStorage Processor (SP)The SP provides the intelligence of the sto
55-10EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareFigure 5-8 Storage System with Two SPs Connected to the Same
5Planning Your Hardware Components5-11Storage System HardwareStorage-system caching provides significant performance enhancement. Read caching is avai
55-12EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareConfiguration Tradeoffs - Unshared StorageFor each storage-s
5Planning Your Hardware Components5-13Storage System HardwareTable 5-1 High-Availability Options, Deskside Unshared StorageFor rackmount systems, the
55-14EMC Fibre Channel Storage Systems Configuration Planning GuideStorage System HardwareHardware Data SheetsThe hardware data sheets shown in this s
5Hardware Data Sheets5-15Storage System HardwarePower requirementsVoltage rating: 100 V ac to 240 V ac –10%/+15%, single-phase, 47 Hz to 63 Hz; power