5-14
EMC Fibre Channel Storage Systems Configuration Planning Guide
Storage System Hardware
Hardware Data Sheets
The hardware data sheets shown in this section provide the plant
requirements, including dimensions (footprint), weight, power
requirements, and cooling needs, for DPE, iDAE, DAE, and 30-slot
SCSI disk systems. Sections on cabinets and cables follow the data
sheets.
DPE Data Sheet
For shared storage, a rackmount DPE and one or more rackmount
DAEs are required. For unshared storage, you can use a rackmount or
deskside DPE and DAE(s). The DPE dimensions and requirements
are shown in the following figure.
DPE Dimensions and Requirements
Width
52.1 cm
(20.6 in)
Depth
74.7 cm
(30 in)
Height
68 cm
(26.8 in)
Height
28.6 c
m
(11.3 in
)
6.5 U
Deskside model Rackmount model
Width
44.5 cm
(17.5 in)
Depth
70 cm
(27.6 in)
SPS mounting tra
y
height 4.44 cm
(1.75 in), 1 U;
depth 54.1 cm
(21.3 in)
Weight (without packaging) Deskside Rackmount
Maximum (max disks, SPs,
LCCs, PSs):
144 kg (316 lb) 52 kg (115 lb)
with 2 SPSs 165 kg (364 lb) 74 kg (163 lb)