EMC QLogic Installation Guide Page 144

  • Download
  • Add to my manuals
  • Print
  • Page
    / 150
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 143
142
EMC Fibre Channel and iSCSI with QLogic Host Bus Adapters in the Windows Environment
Troubleshooting
Solution Upgrade to the latest HBA driver. This was corrected for Windows
2000 in 8.2.2.25 and later drivers. Windows 2003 driver 8.2.2.20 and
later already contain this correction.
Problem 4
EMC Knowledge base solution emc69308 — Direct-connect to EMC
CLARiiON CX200 reports incorrect queue full error messages. Even
under light I/O, a host may log a message noting that disk has
reached a queue-full state similar to the following in the Windows
event viewer:
Event ID: 11
Source: ql2300
Description: The driver detected a controller error on \Device\Scsi\ql2300x.
Data (words): offset 34 = F003001C [ErrorCode: Target device queue full].
Solution Upgrade to the latest HBA driver. This was corrected in version
8.2.2.25 and later drivers.
Problem 5
Windows 2000 hosts running less than SP4 could be susceptible to
data loss during LUN expansion operations.
Solution This issue is corrected by Microsoft in SP4, or by applying hot fix
327020. Refer to EMC Knowledge base solution emc73538 and
Microsoft Knowledge Base article 327020 for more information.
Problem 6
For Windows 2003, the STORPort drivers 8.2.3.26 with Microsoft
hotfix Q823728 and earlier do not yet fully support all Microsoft VSS
functions.
Solution This was first corrected in Microsoft QFE hot fix Q837413 and to be
used with minimum 8.2.3.27 driver. You should also use minimum
Microsoft VSS QFE 833167.
Page view 143

Comments to this Manuals

No comments